4 troubleshooting – Applied Motion TSM17P-1AG User Manual

Page 18

Advertising
background image

18

Rev. A

920-0086

TSM17P Hardware Manual

4 Troubleshooting

LED Error Codes
The TSM17P uses red and green LEDs to indicate status. When the motor is enabled, the green

LED flashes slowly. When the green LED is solid, the motor is disabled. Errors are indicated by

combinations of red and green flashes as shown below. This feature can be disabled for certain

warnings but not for alarms. See software manual for information on how to do this and which

warnings may be masked.

Code

Error

solid green

motor disabled

flashing green

motor enabled

1 red, 1 green

position limit

1 red, 2 green

drive disabled

2 red, 1 green

ccw limit

2 red, 2 green

cw limit

3 red, 1 green

over temperature

3 red, 2 green

internal voltage bad

3 red, 3 green

non-volatile memory error

4 red, 1 green

over voltage

4 red, 2 green

under voltage

4 red, 3 green

non-volatile double error

5 red, 1 green

over current

5 red, 2 green

current limit

6 red, 1 green

open winding

6 red, 2 green

encoder failure

7 red, 1 green

communication error

7 red, 2 green

save failed

Advertising
This manual is related to the following products: