Installation and connection

SKQ 2-01

© AXING AG – state of the art: July 2012 – Reserving change in design and type

Page 7

3.2 Single operation mode of SKQ 2-01

Before installing modules, the power supply must be switched off. To avoid dangerous overvoltages,
(attention: risk of fire/death), the head-end cassette must be grounded according to EN 50083-1, EN
60728-11:2010. Use the grounding screw attached to the device (see ã in fig. 2 on page 5).

In single operation mode of the SKQ 2-01, the power supply is provided by DC injection socket (see 9
in fig. 2 on page 5) . A separate power supply unit SKZ 5-00 is required for it. More units are connected
by means of the DC loop-through. One DC connection cable SKZ 4-00 each is included in the scope of
delivery of SKQ 2-01. Max. 4 pieces SKQ 2-01 may be connected together in single operation mode.

Fig. 4

Assembly and connection of a single twin module

Fig. 5

Assembly and connection of up to four twin modules

In single operation mode of the SKQ 2-01 the outputs of twin modules must be combined together by a
distributor. The input distributors (SKV 2..8-00) in connection with F-double sockets (CFA 3-00) may be
used.

SKQ 2-01

4 × SKQ 2-01