Delta Electronics Elevator Drive VFD-VL User Manual
Page 129

Chapter 4 Parameters|
4-74
Revision Nov. 2008, VLE1, SW V1.03
06-26
PTC (Positive Temperature Coefficient) Detection Selection
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0
Settings
0
Warn and keep operating
1
Warn and ramp to stop
It is used to set the treatment after detecting PTC.
06-27
PTC Level
Unit: 0.1
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 50.0
Settings
0.0
to
100.0%
It is used to set the PTC level, and the corresponding value for 100% is max. analog input
value.
06-28
Filter Time for PTC Detection
Unit: 0.01
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Factory setting: 0.20
Settings
0.00 to 10.00 sec
06-29
EPS Voltage
Unit: 0.1
Control
mode
VF
VFPG
SVC
FOCPG TQCPG FOCPM
Settings
48.0~375.0Vdc
Factory setting: 48.0
96.0~750.0Vdc
Factory setting: 96.0
It is used with the setting 43 (EPS function) of Pr.02-01~02-08 (Multi-Function Input
Command).