Chapter 4 Parameters|
4-84
Revision Nov. 2008, VLE1, SW V1.03
08-03
Rated Speed of Motor (rpm)
Unit: 1
Control
mode
FOCPM
Factory setting: 1710
Settings
0 to 65535
It is used to set the rated speed of the motor and need to set according to the value indicated
on the motor nameplate.
08-04
Number of Motor Poles
Control
mode
FOCPM
Factory setting: 4
Settings
2 to 96
It is used to set the number of motor poles (must be an even number).
08-05
Rs of Motor
Unit: 0.001
Control
mode
FOCPM
Factory setting: 0.000
Settings
0.000~65.535
Ω
08-06
Ld of Motor
Unit: 0.1
Control
mode
FOCPM
Factory setting: 0.0
08-07
Lq of Motor
Unit: 0.1
Control
mode
FOCPM
Factory setting: 0.0
Settings
0.0~6553.5mH
08-08
Reserved
08-09
Angle between Magnetic Field and PG Origin
Unit: 0.1
Control
mode
FOCPM
Factory setting: 360.0
Settings
0.0~360.0
°
This function is used to measure the angle between magnetic field and PG origin.
08-10
Magnetic Field Re-orientation
Control
mode
FOCPM
Factory setting: 0
Settings
0
Disable
1
Enable