Group 8 pm motor parameters – Delta Electronics Elevator Drive VFD-VL User Manual
Page 69

Chapter 4 Parameters|
4-14
Revision Nov. 2008, VLE1, SW V1.03
Group 8 PM Motor Parameters
Pr.
Explanation
Settings
Factory
Setting
VF
VF
PG
SVC
FOC
PG
TQC
PG
FOC
PM
08-00
Motor Auto Tuning
0: No function
1: Only for the unloaded motor, auto measure the angle
between magnetic field and PG origin (08-09)
2: For PM motor parameters
3: Auto measure the angle between magnetic field and PG
origin (08-09)
0
○
08-01 Full-load Current of Motor
40-120%
#.##
○
08-02
Rated power of Motor
0.00~655.35 kW
#.##
○
08-03
Rated speed of Motor (rpm) 0~65535
1710
○
08-04 Number of Motor Poles
2~96
4
○
08-05 Rs of Motor
0.000~65.535
Ω
0.000
○
08-06 Ld of Motor
0.0~6553.5mH
0.0
○
08-07 Lq of Motor
0.0~6553.5mH
0.0
○
08-08 Reserved
08-09 Angle between Magnetic
Field and PG Origin
0.0-360.0
°
360
○
08-10 Magnetic Field Re-
orientation
0: Disable
1: Enable
0
○