When using multi-function input terminals to switch ASR1/ASR2, the diagram will be shown as
follows.
ON
OFF
ASR 1
0.1 sec
OFF
0.1 sec
ASR 1
ASR 2
Setting multi-function input terminal to 17
(ASR1/ASR2 switch)
10-18
ASR Primary Low Pass Filter Gain
Unit: 0.001
Control
mode
VF
VFPG
SVC
FOCPG FOCPM
Factory Setting: 0.008
Settings
0.000 to 0.350 sec
It defines the filter time of the ASR command.
When setting to 1, this function is disabled.
10-19
Zero Speed Gain (P)
Unit: 0.01
Control
mode
FOCPM
Factory Setting: 80.00
Settings
0.00 to 655.00%
When Pr.11-00 is set to Bit 7=1, Pr.10-19 is valid.
10-20
Zero Speed/ASR1 Width Adjustment
Unit: 0.01
Control
mode
VFPG
FOCPG
FOCPM
Factory Setting: 5.00
Settings
0.0
to
120.00Hz
10-21
ASR1/ASR2 Width Adjustment
Unit: 0.01
Control
mode
VFPG
FOCPG
FOCPM
Factory Setting: 5.00
Settings
0.0
to
120.00Hz
These two parameters are used to decide width of slope of ASR command during zero speed
to low speed or Pr.10-17 to high speed.