Pls - plasma lift and swivel – Future Automation PLS User Manual

Page 11

Advertising
background image

In

st

all

at

io

n

: S

ta

ge

6

Page 10 of 22 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

PLS - Plasma Lift and Swivel

Adjusting the Flap Up Position

CABINET TOP - SIDE VIEW

By adjusting the white screw, at each side
of the lift, you can adjust the tilt of the flap.

CABINET TOP - PLAN VIEW

By loosening the M6 bolts on each side under the
flap, you can adjust the position of the flap in the
hole in the cabinet top. Aim for a 3mm gap all round.

CABINET TOP - SIDE VIEW

By winding the push rods on each side, you
can adjust the height of the flap in order to
get it level with the cabinet top. Be sure to
lock the nut securely once adjusted. Make
sure the black plate doesn't touch the inside
of the cabinet. This can cause strain on the
motor, leading to failure.

Advertising