Pls - plasma lift and swivel – Future Automation PLS User Manual

Page 19

Advertising
background image

PROTOCOL

ACTION

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

Beam OUT no movement to swivel

fa_right Carriage Return (Enter )

Device OUT RIGHT limit

fa_left Carriage Return (Enter )

Device OUT LEFT limit

fa_preset Carriage Return (Enter )

Device to PRESET memory position

fa_a Carriage Return (Enter )

Device OUT to memory position a

fa_b Carriage Return (Enter )

Device OUT to memory position b

fa_c Carriage Return (Enter )

Device OUT to memory position c

fa_stop Carriage Return (Enter )

STOPS the device at any position

In

st

all

at

io

n

: I

R

C

on

tro

l

Page 18 of 22 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

PLS - Plasma Lift and Swivel

Operation Details

DC1
Low voltage power output for motor drive.
LED’s to show operation of limit switches
and positional counters

Mains Voltage Input

IR LED

IR Input Jack

RS232

Contact Closure























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return (Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND