Signal wiring, Protocol connectivity, Installation – ILUMINARC Ilumiline™ Inground Tri-12 IP User Manual

Page 14

Advertising
background image

Installation

10

Ilumiline Inground IP Optic 25 Series User Manual Rev. 10



USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last product) to 300 ~ 455
m (985 ~ 1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the
electrical

characteristics of the
Belden® 9841 cable for
EIA RS-485 applications.
You may also use CAT5,
5e, or CAT6 LAN cable.

Signal Wiring

To provide signal to either of the Ilumiline Inground IP products, you have two options.
· Connect the bare-ended IP67 rated signal cable from the product to two IP67 rated

signal connectors (DMX In and DMX Out).

· Use an IP67 rated junction box. In so, make sure to use IP67 rated conduit.

Protocol Connectivity

Ilumiline Inground IP products use the USITT DMX 512 Protocol. The procedure below
illustrates the recommended connection method.




















Advertising