D*AP4

66

Setup GUI – EVENTS – Events – Measurement Events


The measurement event as part of an action can control the integrated measurement of the processed
programs:


For each measurement event you can assign one of the possible control functions.


Setup GUI – EVENTS – Events – I/O Events


At the moment I/O events are restricted to control the GPOs of the D*AP4:




Each GPO (when incorporated into that I/O event) can be

set to the behavior as follows:

Clear

Turns a GPO off that was previously
turned on.

Set

Turns a GPO on.

Follow

The GPO follows the state of the trigger.

Toggle

The trigger will toggle that GPO.
Be careful because it needs a definite
known starting condition to work properly.


To illustrate the function we have setup GPO 1 for that
"Alarm GPO" event (this is the one where the alarm bell
is connected).