Junger Audio d02 - Digital Dynamics Processor User Manual

Page 22

Advertising
background image

3. CONTROL AND DISPLAY ELEMENTS

The DISPLAY button has a second function in addtion to changing the
display mode. It is used for setting the internal digital reference level, which is
the maximum output level which the limiter will allow to be output by the unit.
Hold down the display button continuously for a few seconds and the unit will
enter internal digital reference level setting mode. The GAIN display flashes
and shows the digital reference level.

Setup selections
using display key


The maximum output level permissable for the unit (internal digital reference
level) can now be changed in 1dB steps within the range -15dBFs to 0dBFs
by pressing the INC and DEC buttons. The reference level to be used when
using the analog input and the reference level to be used when using the
digital input can be set independently.

3-6

Advertising