Secondary safety cables MUST be used with the PT-10 and should be
secured to a structural point NOT associated with the PT bracket or
loudspeaker. This secondary safety should be connected between the
loudspeaker and the mounting surface!

PT-30 Installation



The PT-30 is available in two versions. The “standard” version is made with 304 grade
stainless steel. The PT-30 is also available in a “Marine grade” version that uses 316
grade stainless steel. The PT-30 was designed for use on small diameter round and
square/rectangular poles.

See important note on page 3 regarding mounting in “Marine” environments!

For square/rectangular poles the minimum flat dimension must be 3.75 inches
(95.25mm) and for round poles the minimum required diameter is 4 inches (101.6mm).
The PT-30 was designed for use with the 108IM and its transformer variants and for the
208CIM and its transformer variants only. NO SUBSTITUTIONS ARE ALLOWED!

NOTE: One Systems does not imply suitability of specific pole diameters. Each pole
must be verified by the pole manufacturer or others as to the structural suitability of the
pole for use with the total load of the PT-30, the loudspeaker, and all required safety
factors.

THE PT-30 is designed for pole mounting ONLY! DO NOT wall mount the PT-30!

The PT-30 is shown below. The PT-30 allows a down tilt of 40 degrees in 8 degree
increments.