Installation and operation – Pinnacle Systems NSD User Manual

Page 16

Advertising
background image

11

Installation and Operation

NSD Safety Mat System

NSD-DR-04 (DIN-rail Controller with diagnostics)
Accessible Connections

NOTE: Canadian market wiring is black, red, red, black with 18-guage wiring size.

J1

Diagnostics display plug (used by remote status display option)

The Plug is located under the top cover on the left side of the controller

External:

POWER/OUTPUT PLUG

Terminal No. Usage

1,2,3

+POS, -NEG, EARTH GROUND (24VDC ONLY)

4,5

Safety relay N.O. output (dry contact) (held closed when GREEN)

6,7

Safety relay N.O. output (dry contact) (held closed when GREEN)

8,9,10

Auxiliary relay N.C., COM, N.O.

11,12

Fault relay N.O. (open when faulted)

INPUT / OUTPUT PLUG

Terminal No. Usage

1,2

+pos, -neg External relay checking (option)

24vdc applied across these terminals when external relay is de-energized

3

Remote external zone reset (Ground to reset zone)

4,5

Auxiliary inputs (Ground to activate feature)

6

+24vdc input (Common for terminals 3,4,5) (jumper from term #1 Power/Output)

7

Optional remote RED “STOP” indicator output (Grounded when RED)

8

Optional remote GREEN “RUN” indicator output (Grounded when GREEN)

MAT 1,2,3,4 INPUT

Terminal No. Usage

1,2

20VDC output to mat (1=blue, 2=white)

voltage between 1 & 2 alternates

(1=black, 2=red for single two-dual lead mats)

3,4

Return from mat (3=black, 4=brown)

(3=red, 4=black for single two-dual lead mats)

DEVICENET PLUG (DB-9 female)

Terminal No. Usage

2,7

CANL, CANH (twisted pair data lines)

3,6 Ground