ZAURA RF Module Shell
User Manual
UM023502-0911
read
5
read
Read registers
Syntax
read ofs <len>
Example 1
read 10
D6
Example 2
read 10 5
D6 38 28 07 27
The
read
command displays a subset of the ZAURA RF Wireless Mod-
ule register set. The ofs parameter specifies the zero-based offset of the
first register to read. The optional <len> parameter specifies the number
consecutive registers to read. If <len> is omitted, only the contents of ofs
is displayed. All values must be specified in hexadecimal format.
The ofs parameter must be between
0x00
and
0x1F
.