Uecho, Uecho set the uart in echo or no echo mode – Zilog ZAURA868 User Manual

Page 40

Advertising
background image

ZAURA RF Module Shell

User Manual

UM023502-0911

uecho

34

uecho

Set the UART in Echo or No Echo mode

Syntax

uecho <on|off>

Example 1

uecho

UART echo ON

Example 2

uecho off

UART echo OFF

The ZAURA RF Wireless Module Shell can be configured to echo char-
acters received on UART0 Rx to UART0 Tx. This echo configuration
allows the operator of the console terminal program to see the characters
he or she is typing in the terminal window. However, the terminal pro-
gram will also typically include a

local echo

option in which the termi-

nal program automatically displays characters as they are entered in the
terminal window. Configuring both the PC terminal program and the
ZAURA RF Wireless node to echo UART data will result in two charac-
ters being displayed for every entered character, while disabling

echo

on

both sides means that the operator will be typing blind.

The default ZAURA RF Wireless Module UART echo setting is con-
trolled by the

ZAURA_RF_UartEcho

configuration variable. The value of

this variable can be programmatically modified at run time; it can also be
modified by using the

uecho

console command. If the

uecho

command

is issued without any parameters, it will display the current UART echo
state. To enable UART echo, issue the command

uecho on

. To disable

UART echo, issue the command

uecho off

.