Venting installation instructions – Desa T32N-a SERIES User Manual

Page 10

Advertising
background image

www.desatech.com

116646-01D

10

6.

Noncombustible Exterior Wall:

Position the

horizontal vent cap in the center of the 8

1

/

2

"

round hole and attach to the exterior wall with

four screws (see page 10). Note: The four wood

screws provided should be replaced with ap-

propriate fasteners for stucco, brick, concrete or

other types of sidings. Before attaching the vent

cap to exterior wall, run a bead of non-hardening

mastic (pliable sealant) around the outside edges

to make a seal between it and the outside wall.

Combustible Exterior Wall:

For vinyl siding,

stucco or wood exteriors, a siding standoff may

be installed between the vent cap and exterior

wall. The siding standoff prevents excessive

heat from damaging the siding materials. Siding

material must be cut to accommodate stand-

off. Bolt the vent cap to the standoff. Apply

non-hardening mastic around outside edge of

standoff. Position the standoff/cap assembly in

the center of the 10

3

/

4

" square hole and attach

to exterior wall with wood screws provided (see

Figure 11). The siding standoff must sit flush

against the exterior fascia material.

7.

Combustible Exterior Wall Only:

Slide the wall

firestop over the vent pipe before connecting

horizontal run to vent cap (see Figure 12).

8. Carefully move fireplace, with vent assembly

attached, toward wall and insert vent pipe

into horizontal termination. The pipe overlap

should be a minimum of 1

1

/

4

" (see Figure 13,

page 11).

9.

Combustible Exterior Wall Only:

Slide wall

firestop against interior wall surface and attach

with screws provided (see Figure 12). See

Figure 13, page 11, for horizontal termination

details.

VENTING INSTallaTION

INSTRUCTIONS

Continued

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Figure 11 - Installing Siding Standoff

(Combustible Exterior)

Wood
Screw

Vent
Cap

Cut Siding Away to
Fit Standoff

Wood Screw

Screws

Standoff

Vent Cap

Apply Mastic
to All Four Sides

10. Place fireplace into position and shim with

noncombustible material if needed. Nail or

screw side flanges to framing to secure unit in

place. IMPORTANT: Make sure fireplace is

level before securing. If fireplace is not level

it will not work properly.

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Firestop

Horizontal
Vent Pipe

Figure 12 - Connecting Vent Cap with

Horizontal Vent Pipe

Screw

Apply Mastic to
All Four Sides