VENTING INSTallaTION

INSTRUCTIONS

Continued

Vertical Venting

V = 40' max.

Figure 24 - Vertical Venting Configuration

With No Horizontal Run (Vertical Round

High Wind Termination Shown)

Note: Install
restrictor into inner
collar of fireplace
as shown.

45° Elbow

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and

approved for elevations from 0-2000 feet (USA) and

elevations from 0-4500 feet (Canada).

Fireplaces for High Altitude (models ending in

-HA) are for installation above 4000 feet only.

These fireplaces are equipped with parts specific

for higher altitudes. IMPORTANT: These fireplac-

es can NOT be converted to Propane/LP gas.

When installing a non-high altitude fireplace at an

elevation above 2000 feet (in the USA), you may need

to decrease the input rating by changing the existing

burner orifice to a smaller size. Reduce input 4% for

each 1000 feet above sea level. Check with your local

gas company for proper orifice size identification.

When installing this fireplace at an elevation above

4500 feet (in Canada), check with local authorities.
IMPORTANT:

For horizontal installations

above 2,000 feet, it is recommended that a 12"

extension pipe be added before starter elbow

(see Figure 25) and a round horizontal termi-

nation be used.

Figure 25 - Recommended 12" Extension

for High Altitude Installation

45° Starter
Elbow

1"
Extension

PARTS LIST FOR VENTING KITS
AND COMpONENTS

DESA (5"/8") Pipe & Vent Kits
Number

Description

P58-6

6" Section Double Wall Pipe,

Galvanized

P58-1

1" Section Double Wall Pipe,

Galvanized

P58-4

4" Section Double Wall Pipe,

Galvanized

P58-36

36" Section Double Wall Pipe,

Galvanized

P58-48

48" Section Double Wall Pipe,

Galvanized

PA58-71 Adjustable 7"-1" Section Double

Wall Pipe, Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

VKG-58

Ground Floor Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

16 Screws)

VKB-58

Basement Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

Horizontal Square Termination,

4' Pipe, 90° Elbow, 0 Screws)

VKS-58

Snorkel Vent Kit, Galvanized

(Includes: 45° Elbow, 7"-1"

Adjustable Pipe, Wall Firestop,

36" Snorkel Termination, 4' Pipe,

1' Pipe, 90° Elbow, 6 Screws)