Fireplace installation – Desa T32N-a SERIES User Manual

Page 19

Advertising
background image

www.desatech.com

116646-01D

19

3. Place the blower against the lower rear wall of

the firebox outer wrapper with the exhaust port

directed upward and the thermodisc positioned

up near the fireplace bottom. The thermodisc

must be oriented near the fireplace bottom as

shown in Figure 29, in order to sense tempera-

ture and properly operate. The blower will be

held in position against the back wall by the

magnets incorporated onto the blower housing

(see Figure 29).

4. Be certain that all wire terminals are securely at-

tached to terminals on blower motor and thermal

switch and that the screw for the thermodisc

bracket and green ground wire is tight.

5. Mount the speed control box against the

mounting plate provided in the lower fire-

place cavity by placing the plastic control

shaft forward through the round hole (see

Figure 27, page 18).

6. While supporting speed control, secure control

shaft with lock nut by pushing and turning

lock nut with pliers clockwise until it is tight

against mounting plate. Place control knob

provided on shaft (see Figure 27, page 18).

7. Check to make sure that the power cord is com-

pletely clear of the blower wheel and that there

are no other foreign objects in blower wheel.

Also double check all wire leads and make sure

wire routing is not pinched or in a precarious

position. Correct accordingly.

8. Turn on power to duplex outlet if previously

turned off per the warning in column 2, page 17.

9. Plug in blower power cord to duplex outlet.

10. The blower will only run when the speed control

knob is in the ON position and the thermal switch

senses temperature after the fireplace begins to

heat up. The blower speed can be adjusted by

rotating the control knob. To turn off, turn knob

fully counterclockwise until it clicks off. If the

blower is ON and has been running with the

fireplace operating, the blower will continue to

run for a short time after the fireplace has been

turned off. As the thermal switch cools down,

the blower shuts down automatically.

11. Peel off the backing paper and stick the sup-

plied wiring diagram decal on the firebox bot-

tom approximately 12" in front of the blower

(see Figure 28, page 18).

FIREplaCE

INSTallaTION

Continued

Thermodisc

Figure 29 - Blower Model BKT

Air Flow
Direction

Route BKT Blower
Through This Area

Magnets

Blower
Location

Side View Firebox Bottom

Black
Wire

Phillips
Screw

Blue
Wire

Ring
Terminal on
Green Wire

White
Wire

Thermal
Switch

Thermal
Switch
Bracket

Power Cord

Air Flow
Direction

Magnetic
Strips

Figure 30 - Blower Wiring Diagram for

Thermostat-Controlled Models

Blower Wiring Diagram

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and dan-

gerous operation. Verify proper

operation after servicing.

Blue

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Advertising
This manual is related to the following products: