Fireplace installation – Desa T32N-a SERIES User Manual

Page 22

Advertising
background image

www.desatech.com

116646-01D



Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 34).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas fireplace or opening main gas

valve located on or near gas meter for natural

gas fireplace or using compressed air.

3. Check all joints from propane/LP supply tank

for propane/LP or gas meter for natural gas to

equipment shutoff valve (see Figure 35 or Figure

36). Apply noncorrosive leak detection fluid to

all joints. Bubbles forming show a leak. Correct

all leaks at once.

Open

Closed

Equipment
Shutoff Valve

Figure 34 - Equipment Shutoff Valve

pRESSURE TESTING FIREpLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 34).

2. Open main gas valve located on or near gas

meter for natural gas or open supply tank

valve for propane/LP gas.

3. Make sure control knob of fireplace is in the

OFF position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 35 or Figure 36).

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak. Correct

all leaks at once.

5. Light fireplace (see Operating Fireplace,

page 26). Check all other internal joints for

leaks.

6. Turn off fireplace (see To Turn Off Gas to Appli-

ance, page 27).

INSTALLING OpTIONAL WALL
MOUNT SWITCH - GWMS2

1. Connect one terminal of 25 ft. wire for the

wall switch to the TPTH terminal on the

valve. Connect remaining wire terminal to the

TH terminal on the valve. Make sure that the

wire terminals are in the positions on the unit

as pictured in Figure 37. If wires are not con-

nected as shown the switch will not work.

2. Route the 25 ft. wire through openings pro-

vided on the sides of the burner system to a

convenient location to mount your switch.

3. Connect one bare wire end to each of the

terminals of the GWMS2 wall switch.

4. Install the wall switch and cover in the wall.

Figure 35 - Checking Gas Joints for

Propane/LP Gas Fireplace

Propane/LP
Supply Tank

Gas Valve

Equipment Shutoff Valve

Figure 36 - Checking Gas Joints for

Natural Gas Fireplace

Gas
Meter

Gas Valve

Equipment Shutoff Valve

Figure 37 - Connecting Wall Switch to

Control Valve

To Wall
Switch
Accessory

FIREplaCE

INSTallaTION

Continued

Advertising