SpECIFICaTIONS

(V)T32N-A Series and CGDV32NR

• Rating: 12,000/18,000 Btu/Hr

• Type Gas: Natural Gas Only

• Ignition: Piezo

• Manifold Pressure: 3.5" W.C.

• Minimum Inlet Gas Pressure (W.C.): 5.5"

• Dimensions (H x W x D) (Firebox only - Does

not include nailing flanges or standoffs):

32

1

/

4

" x 34

1

/

2

" x 16

5

/

8

"

• Fireplace Weight* - 80 lb

• Shipping Weight* - 83 lb

*For refractory lined models add 45 lb
(V)T32P-A Series and CGDV32PR
• Rating: 11,000/17,000 Btu/Hr

• Type Gas: Propane/LP Gas Only

• Ignition: Piezo

• Manifold Pressure: 10" W.C.

• Minimum Inlet Gas Pressure (W.C.): 11"

• Dimensions (H x W x D) (Firebox only - Does

not include nailing flanges or standoffs):

32

1

/

4

" x 34

1

/

2

" x 16

5

/

8

"

• Fireplace Weight*: 80 lb

• Shipping Weight*: 83 lb

*For refractory lined models add 45 lb

REplaCEMENT paRTS

Note

: Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

pARTS UNDER WARRANTY

Contact authorized retailers of this product. If

they can not supply original replacement part(s),

call DESA’s Technical Service Department at

1-866-672-6040.

When calling DESA, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

pARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If

they can not supply original replacement part(s),

call DESA at 1-866-672-6040 for referral infor-

mation.

When calling DESA, have ready

• model number of your fireplace

• the replacement part number

SERVICE hINTS

When Gas pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low (propane/

LP units only)

You may feel your gas pressure is too low. If so,

contact your local gas supplier.

TEChNICal SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA’s

Technical Service Department at 1-866-672-6040.

When calling, please have your model and serial

numbers of your heater ready.

You can also visit DESA’s technical service web site at

www.desatech.com

.

Advertising
This manual is related to the following products: