SaFETy INFORMaTION

Continued

9. Do not use this fireplace to cook food or burn

paper or other objects.

10. This appliance, when installed, must be electri-

cally grounded in accordance with local codes

or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or

the Canadian Electrical Code, CSA C22.1.

11. Do not use fireplace if any part has been under

water. Immediately call a qualified service per-

son to arrange for replacement of the unit.

12. Do not operate fireplace if log is broken.

13. Provide adequate clearances around air

openings.

pRODUCT

IDENTIFICaTION

Figure 1 - Direct-Vent Fireplace with

Millivolt Ignition

Glass Door Assembly

ON/OFF/REMOTE Switch
(Optional Installation)

Log
Set

Lava
Rock

Glowing
Embers

Upper Louver Panel

Lower
Louver
Panel

Flue
Collar

Nailing
Flange

Grate
Assembly

Piezo
Ignitor
Control
Valve

Blower Switch
(Optional Installation)

lOCal CODES

Install and use fireplace with care. Follow all local

codes. In the absence to local codes, use the cur-

rent National Fuel Gas Code ANSI Z223.1/NFPA

54* (USA) or the current CSA-B149.1 Installation

Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

pRODUCT FEaTURES

These are a few facts that can help you understand

and enjoy your direct-vent fireplace:

• The venting system may be routed to the out-

side of your home in several ways. It may vent

through the roof (vertical) or it may vent to an

outside/exterior wall (horizontal). The vent

pipe installation is very important to allow for

proper operation. You must follow the venting

instructions very carefully for either vertical or

horizontal applications.

• This fireplace may be installed in any room of

your house provided all local codes and these

installation instructions are followed.

• This fireplace does not require electricity to

operate.

• Only the blower requires electricity if installed.

If you plan to install the blower at a later date,

outlet must be wired at the bottom of the fire-

place when framing.

• A piezo ignitor and ceramic electrode create

sparks to ignite the pilot light. It does not require

any matches, batteries or any other sources of

ignition to light the pilot.

• Each time you turn on your fireplace, you may

notice some amount of condensation on the in-

side of the fireplace glass. This is normal and will

disappear after 10-20 minutes of operation.

• Your direct-vent gas fireplace system (fireplace

and venting) is a balanced and sealed gas op-

erating unit. It requires approximately 10-20

minutes of operating time before the flame

pattern stabilizes.

• Fireplaces with the suffix of -HA have been

designed to operate at altitudes of 4000 feet

and above.