Front panel -3, 4 front panel – AMETEK CW-M User Manual

Page 13

Advertising
background image

Elgar CW-M Series

M161570-01

2-3

2.4 FRONT PANEL

Controls

Power On/Off switch

Output On/Off/Reset switch: Operates output isolation relays. Off also resets

faults.

Voltage Range switch: Selects 135 Vmax or 270 Vmax range

(Output switch must be off to change range)

Meter Select switch: Current/frequency select

Output Voltage: Adjusted using 10

–turn potentiometer

Output Current: Adjusted using 10

–turn potentiometer

Output Frequency: Adjusted using 10

–turn potentiometer

Overvoltage Protection: Settable 5 to 300 VRMS using a 15

–turn screwdriver

adjust potentiometer

Displays

Voltage: 4

–digit, 7–segment large, green LED display

Current or Frequency: 4

–digit, 7–segment large, green LED display

Protection and Isolation

Overvoltage: Set screw adjustable

Overcurrent: 10

–turn potentiometer

Accuracy: ±2% of range for linear loads with current >0.2 A for CW801M and

CW1251M, >0.4A for CW2501M.

Overtemperature: Internal monitor

Isolation Rating: 500V between either output terminal and chassis

Indicators

Output On: Green LED

Voltage Mode: Green LED

Current Mode: Green LED

Slave Mode: Green LED

Fault Mode: Red LED

Output Connector

Universal single socket connector for front panel power out on CW 801M and
CW 1251M

Line and neutral terminals can be switched through rear connector interconnect

Advertising