Remote output on/off control -23, Remote output on/off by contact closure -23, Remote output on/off control – AMETEK SGA Series User Manual
Page 73

Sorensen SGA Series
Operation
M550129-01 Rev AG
3-23
3.8
REMOTE OUTPUT ON/OFF CONTROL
Remote output on/off control may be accomplished by contact closure, or
through an opto-isolated interface with external voltage sources, AC/DC or
TTL/CMOS.
3.8.1
REMOTE OUTPUT ON/OFF BY CONTACT CLOSURE
Application of a contact closure between Pins J1-5 and J1-6 will enable the
output. See Figure 3-18 for connection requirements.
1
25
14
6
ON/OFF 5
Figure 3-18. Remote Output ON/OFF Control by Contact Closure
3.8.2
REMOTE OUTPUT ON/OFF CONTROL BY EXTERNAL SOURCE
Application of AC/DC voltage between Pins J1-1 and J1-2, or TTL/CMOS
voltage between Pins J1-14 and J1-2, will turn on the power supply; this
interface is opto-isolated from circuit common, Pins J1-6 and J1-24. See
Figure 3-19 and Figure 3-20 for connection requirements.
25
14
ISO ON/OFF 1
+
-
AC OR DC
SOURCE
ISO RTN 2
Figure 3-19. Remote Isolated Output ON/OFF Using AC or DC Source