API Audio THE BOX User Manual

Page 54

Advertising
background image

API “The BOX”

Operator’s Manual

54

Compressor Circuit Topologies

The 527 compressors can be set to operate in two circuit topologies:

OLD: Feed-back: The RMS detector receives the signal from after the VCA

NEW: Feed-forward: The RMS detector receives the signal from before the VCA


OLD: Feed-Back Compression

In a feed-back compressor, the RMS detector gets its signal from the output of the
gain reduction device (VCA). This is how older API 525, 1176 type, and 660 type
compressors work. This yields a smoother, softer, more transparent sound.


NEW: Feed-Forward Compression

In a feed-forward compressor, the RMS detector normally gets its signal from a split of
the input signal. (The detector path can alternately get its signal from a Side Chain
Input.) With this method, the RMS detector sends a signal to the VCA that is an exact
ratio of the desired compression set by the RATIO control. This is how many new VCA
based compressors work. This can yield more aggressive compression and a harder,
more affected sound.


TYPE (NEW-OLD): Toggles between feed-back and feed-forward
compressor topologies

OLD feed-back is selected when not engaged

NEW feed-forward is selected when engaged

Illuminates when engaged

Advertising