Software Installation
PCIE-8120 Installation and Use (6806800R89C)
37
The first argument defines the MAC of the MSW network interface. The second argument
defines the number of iterations. In the example above, just one loop is executed. To run
continuously use -1 for the number of iterations:
# ./12_dsp_audio_transcode_net_api 00:80:42:2C:7B:D8
-1
The test passes, if all of the “Err”, “Drop”, “Slip” counters are zero. In this case the following
output is provided:
*** Loop: 0 ***
+-- VOC TERM MC STATISTICS (DSP 00) ----------------------
| RxOutPktCnt : 2457645
| RxInSidPktCnt : 0
| RxNoPktCnt : 2448744
| RxBadPktTypeCnt : 0
| RxBadRtpPayloadTypeCnt : 0
| RxBadPktHdrFormatCnt : 0
| RxBadPktLengthCnt : 0
| RxMisorderedPktCnt : 0
| RxLostPktCnt : 0
| RxBadPktChecksumCnt : 0
| RxUnderrunSlipCnt : 0
| RxOverrunSlipCnt : 0
| RxLastVocoderType : 0
| RxVocoderChangeCnt : 0
| RxMaxDetectedPdv : 173 (in 125 us)
| RxDecdrRate : 0
| RxMaxJitterCurrentDelay : 165 (in 125 us)
| RxJitterEstimatedDelay : 0 (in 125 us)
| RxJitterEstimatedDelay : 0 (in 125 us)
| RxJitterClkDriftingCorrectionCnt : 0
| RxMaxJitterInitializationCnt : 1
| RxCircularBufferWriteErrCnt : 0
| RxApiEventCnt : 0
| TxCurrentVocoderType : 0
| TxInPktCnt : 2456643