Extra Room Power Heat Duct Instructions

SKU 98500769

Page 11 of 11

12/2/13 - 17601067

© Travis Industries, Inc.

Operating Instructions

Allow the fireplace to reach normal operating temperature. Then use the wall-mounted rheostat to
operate the blower speed.

Fireplaces with Internal Thermodisk

(864 HO, Xtreme 6020, 36 CF ST/Pier, 1080 CF)

The blower will automatically shut off after the fireplace cools.

Fireplaces without Internal Thermodisk

(864 TRV & ST, 564 HO)

Turn the blower off when the fireplace is not in operation.

OFF

Turn the dial all

the way counter-

clockwise until it

clicks off.

HIGH

The high position is

all the way counter-

clockwise,

without

clicking off.

LOW

Turn the dial

all the way

clockwise.

Maintenance Instructions

Once a year the grill should be removed and the blower area cleaned. Use a vacuum to clean around the
squirrel-cage blower, being careful not to damage any of the blades.

Grill

Phillips

Screwdriver

Use a vacuum cleaner to remove

any debris from the power vent

blower.

Advertising