Extra Room Power Heat Duct Instructions

SKU 98500769

Page 8 of 11

12/2/13 - 17601067

© Travis Industries, Inc.

Blower Box Wiring

Remove the cover from
the blower box.

a

b

Insert sheathed cable through the cable clamp.
After the wires have been connected tighten the
clamp to secure the cable.

Secure the ground wire to the ground stud inside the
blower box by tightening the included nut over the
ground wire. Re-attach the cover removed in step
"a".

Attach the hot (black) and common (white) wires to the
leads coming from the wires (use wire nuts).

c

d

Standard
Screwdriver

Phillips
Screwdriver

Ground Wire

Rheostat Junction Box Wiring

NOTE:

There are two junction boxes included (new construction and retrofit). Use the appropriate
junction box for your installation.

NOTE:

The Xtreme 6020 is installed without the rheostat (the blower is controlled by the remote).
Route the wire from the blower directly to the fireplace.

a

Force the sheathed cable through
one of the locking flaps on the
junction box (repeat for the other
cable). Some force is needed.
The flap will lock the cable in place.

Attach the cover plate with
the included screws and
attach the knob.

Attach the common (white) wires
together. Attach the ground
(exposed or green) wires together.
Then attach each of the hot (black)
wires from the cables to the two
wires on the rheostat (orientation
does not matter). Carefully pack
the wires into the junction box.

c

b

From
Blower Box

To Fireplace or Power Supply

(see wiring diagrams)

Standard
Screwdriver

NOTE:

Two junction

boxes are included -
use the best box for
your installation.