Analog Output Channel Object

29

IPxxxx-B520

Instance Attributes

100

(64hex)

get/set

1

Register 0

DWORD

Value of Register 0 of
the

analog

output

channel

See semantics

:

:

:

:

:

:

106

(6Ahex)

get

Register 6

DWORD

Diagnosis Register

See semantics

:

:

:

:

:

:

163

(A3hex)

get/set

1

Register 63

DWORD

Value of Register 63 of
the

analog

output

channel

See semantics

170

(AAhex)

get

Value Length

USINT

Value length in Bytes

1: before writing the registers the write protection of the registers has to be disabled.





Semantics


Status

The Status of an Analog Output Point indicates the following conditions:

Value

Description

0

OK, no failure

1

internal IO Error
Idle Mode, no Output data via DeviceNet
Diagnostics (depends on IPxxxx, see manual)
dle Mode, no Output data via DeviceNet



Fault State / Idle State

The attribute values are according to the adjustment of the “IO Error Action
Attribute” of the IP Config Object. (see chapter IP Config Object)

Value

Description

0

hold last state

1

Low Limit, reset output