4 handling, 1 transport, 2 packaging – BECKHOFF AL2000 Linear servomotor User Manual

Page 13: 3 storage, 4 maintenance / cleaning, 5 disposal, 4handling

Advertising
background image

Handling

4

Handling

4.1

Transport

• Climate category: 2K3 according to EN 60721

• Transport temperature: ­25 °C ­ +70 °C, max. fluctuation 20 K/hour

• Transport humidity: relative humidity 5% ­ 95%, non­condensing

• The linear servomotor may only be transported by qualified personnel and in the manufacturer's origi­

nal recyclable packaging.

• If the packaging is damaged, check the motor for visible damage. Inform the transport company and, if

necessary, the manufacturer.

4.2

Packaging

• Cardboard packaging

Motor type

Max. stacking height

AL2xxx

­

4.3

Storage

• Climate category

2K3 according to EN 60721

• Storage temperature:

­25 °C ­ +70 °C, max. fluctuation 20 K/hour

• Air humidity:

relative humidity 5% ­ 95%, non­condensing

• Max. stacking height:

see table Packaging

• Storage time:

without limitation

• Store only in the manufacturer’s original recyclable packaging

4.4

Maintenance / Cleaning

• Maintenance and cleaning only by qualified personnel.

• Opening the motor invalidates the warranty.

• Clean the housing with isopropanol or similar.

Attention

Destruction of the linear servomotor

Never immerse or spray the linear servomotor.

Proper functioning of the bearings and buffers, and guidance of the movable lines, must all be tested.

4.5

Disposal

In accordance with the WEEE 2002/96/EC Directives we take old devices and accessories back for
professional disposal, provided the transport costs are taken over by the sender. Send the devices with the
note “For disposal” to:

Beckhoff Automation GmbH
Eiserstrasse 5
33415 Verl

Linear servomotor AL2xxx