2 attachment of the magnetic plates – BECKHOFF AL2000 Linear servomotor User Manual

Page 26

Advertising
background image

Mechanical installation

7.3.2

Attachment of the magnetic plates

1. Make sure that the magnetic plate is correctly aligned. At the end, all the magnetic plates that have

been fitted must be aligned in the same direction. 
Example:
All magnetic plates must be attached in such a way that the positioning holes point to the right upper
corner. This is very important, since the linear motor can make an uncontrolled movement if they are
mounted incorrectly.

2. Fasten the magnetic plate to the machine bed with the stainless steel screws. The depth of the thread

should be at least 6.5 mm and the tightening torque 2.5 to 3.5 Nm. All the holes must be used!

3. Remove the protective plate from the mounted magnetic plate. Make sure that the support surface is

free from dust and small particles.

Linear servomotor AL2xxx