7.5

Dismantling sequence

WARNING

Damage due to uncontrolled magnetic attractive forces

The dismantling sequence given in these instructions must be followed. A different se­
quence can give rise to dangerous situations, and can lead to damage resulting from un­
controlled magnetic attraction.

Dismantling sequence:

1. Check that there is no voltage and secure against being switched on again.

2. Disconnect the electrical cables.

3. Disconnect the hoses of the water cooling unit (if installed).

4. Move the carriage to one side. Secure the carriage in such a way as to prevent unwanted movement.

5. Cover each magnetic plate that needs to be removed with a neutralising protective plate.

6. Remove one or more magnetic plates. The distance between the magnetic plates and the coil unit dur­

ing this process should not be less than 10 cm.

7. Move the carriage to the other side. Secure the carriage in such a way as to prevent unwanted move­

ment.

8. Cover each magnetic plate that needs to be removed with a neutralising protective plate.

9. Remove the remaining magnetic plates.

10. Remove the coil unit from the carriage.

Linear servomotor AL2xxx