4 polarity test – BECKHOFF AL2000 Linear servomotor User Manual

Page 43

Advertising
background image

Electrical installation

T (ºC)

0

10

20

30

40

50

60

70

80

90

100

110

120

130

RKTY ()

815

886

961

1040

1123

1209

1300

1394

1492

1594

1700

1810

1923

2041

The sensor requires a continuous current of between 0 and 2 mA. The resistance does not respond linearly
to temperature. A linear current/temperature curve can be obtained with a resistance circuit as shown in the
diagram below. The basic tolerance is around ±5ºC (with shunt resistors). 

8.4

Polarity test

Attention

Protection of the linear servomotor

Before the test, make sure that the linear motor system has suitable electrical and mechan­
ical protection.

There is one way of checking the polarity. By means of moving the carriage it is possible to determine
whether the direction of movement of the motor corresponds to the count direction of the feedback. If this is
the case, the motor is connected correctly. Otherwise, two phases in the motor cable ­ phases 1 and 3 ­
must be swapped.

All linear servomotors from Beckhoff are wired and connected in exactly the same way, so that a single test
is sufficient in order to determine the polarity of a motor/graduated rule combination. If more than one axis is
being constructed in a similar way, the polarity will be identical.

Linear servomotor AL2xxx

43

Version 4.0

Advertising