1 - electrical installation, Connecting feeder cable, N (l – Caple CR13400 User Manual

Page 5: 230 v

Advertising
background image

5

1 - Electrical Installation

Connecting feeder cable

To connect the feeder cable to the
cooker it is necessary to:

– Remove the 6 screws that hold

shield A behind the cooker.

– Open completely the cable clamp D.

– Position the U bolts onto terminal block

B (fig. 1.1) according to the diagram in
fig. 1.2 and fig. 1.3.

– Insert the feeder cable into the cable

save P. The supply cable must be of
a suitable size for the current require-
ments of the appliance; see the
section “Feeder cable section”.

– Connect the phase and earth cables

to terminal B according to figures 1.2
and 1.3.

– Pull the feeder cable and block it

with the cable clamp D

– Re-mount shield A.

N.B. The earth conductor must be left
about 3 cm longer than the others.

Fig. 1.1

PE

1 2 3 4 5

N (L

2

)

L

1

230 V

Fig. 1.2

Feeder cable section
type H05RR-F

230 V

3 x 4 mm

2

(**)

(**) – Connection with wall box connection.

– Diversity factor applied
– A diversity factor may be applied to

the total loading of the cooker only
by a suitable qualified person.

23

4

5

1

230 V ~

N

(L

2

)

PE

L1

Red
or
Brown
(Live)

Black
or
Blue
(Neutral)

Green
and
Yellow
(Earth)

Fig. 1.3

PE Earth

N

Neutral

L

Live

P

D

A

B