CDPM Digital Paging Microphone

Setup And Installation Guide

CLOUD ELECTRONICS LIMITED

Table 8.1: Default Jumper Settings

When removing jumpers we recommend that the link remain connected to one leg of the header, to
prevent loss of the link.

When making internal adjustments please ensure that you:

• Disconnect power to the unit before deconstructing. Where the microphone is powered from

another unit, this will mean removing the connection to that unit. For access terminal block
connections, this is best achieved at the mixer end of the connection.

• Only reassemble the unit using the original screws or screws identical to the originals.

Fig 8.1: Jumper locations on CDPM main PCB

J1

+1 to Chime Select

ON

J2

+2 to Chime Select

OFF

J3

+4 to Chime Select

OFF

J4

Terminate Buss

ON

J5

Chime On/Off

ON

J6

Internal Chime On/Off

ON

J7

NVM Reset

OFF

J8

Priority

OFF

J9

Group Lock

OFF

J10

Auto Zone Reset

ON

J11

+8 to Bank Offset

OFF

J12

+4 to Bank Offset

OFF

J13

+2 to Bank Offset

OFF

J14

+1 to Bank Offset

OFF

10

V1 210605

Advertising