Cloud Electronics CDPM Range User Manual

Page 18

Advertising
background image

CDPM Digital Paging Microphone

Setup And Installation Guide

CLOUD ELECTRONICS LIMITED

 

Let us consider an installation where a hotel is divided into 10 separate zones as tabulated
below:

Table 9.1: Required Zones

Paging microphones are required in 4 locations : Reception (Zone 1: Foyer), Kitchen (Zone 3),
Gym (Zone 8:Staff desk) and Security Centre (Zone 10). Both the Reception and Security
Centre microphones need to access all areas, while the kitchen and gym microphones are only
used on their domains. Further to this, both the security and paging microphone need to be
prioritised so that their announcements will override announcements from the kitchen and gym.
The mapping between access and microphone points is shown below:

Table 9.2: Paging point access and priorities

The Gym facilities (zones 6-8) require a separate set of audio sources to the rest of the hotel, so
a Z4

II

four zone mixer is allocated for the Gym facilities. The remaining 7 zones are to be

distributed through a Z8

II

eight zone mixer. The mixers can be used to power one microphone

each, so in this case, the Z8

II

is used to power one of the CDPM-4 microphones and the Z4

II

is

used to power the other CDPM-4. Both the CDPM-12 microphones will need to use separate
CDPM-PSUs.

Paging Point

Description

Required zones Microphone type

Priority

PP1

Reception

1-10

CDPM-12

High

PP2

Security

1-10

CDPM-12

High

PP3

Gym Desk

6-8

CDPM-4

Normal

PP4

Kitchen

2-5

CDPM-4

Normal

Zone Description

Zone Description

1

Foyer

6

Fitness Suite

2

Bar

7

Swimming Pool

3

Kitchen

8

Gym staff desk

4

Restaurant

9

All Accomodation

5

Supplies

10

Security Centre

12

V1 210605

*RECEPTION*

*SECURITY*

GYM

KITCHEN

LEGEND

TERMINAL CONNECTION

RJ45 CONNECTION

FROM OUT TO IN

POWERED CONNECTION

CDPM-PSU

CDPM-PSU

CDPM-12

CDPM-12

CDPM-4

CDPM-4

GYM Mixer

Z4

II

All Other Zones

Z8

II