Ia500, Administrator guide – Code Blue IA500-S SINGLE BUTTON ANALOG SURFACE MOUNT User Manual

Page 11

Advertising
background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-144-E

page 11 of 17

IA500

Administrator Guide

Commands Feature

Description

Command

Range

Default Example

02

Programming

Password

The programming pass-

word can be changed from

default to your choice of

numbers up to 8 digits in

length.

0-8 digits

2258

To modify the default password to

98765, from the keypad, dial: 02-

98765-#

03

Call Length

Timer

Sets duration of the call.

This can be modified to ac-

comodate the end user.

1-99 min.

10 min. To increase the call length duration

from 10 to 25 min., dial: 03-25-#

04

Ring Timer

Ring Timer controls the

amount of time the IA500

is allowed to ring a called

party before the phone

rolls over to dial the next

programmed number

(NOTE: Limited to quality

of line conditions).

05-99 sec.

30 sec.

To increase the ring timer from 30

to 35 sec. dial: 04-35-#

05

Calling Cycle Determines how many

times each number in

memory is dialed before

the IA500 resets to stand-

by state (NOTE: Limited

to quality of line condi-

tions)

1-3 times

2

Decrease the calling cycle from 2

to 1 by dialing: 05-1-#

07

Contact

Closure Relay

Relay Programming: 2 Modes Available

Mode 1: Default. Closed

for the duration of the call

and is uniquely linked to

the RED BUTTON activa-

tion only.

Duration of Call 10 min.

Mode 2: Relay Gate

Control. This feature

disengages the relay from

the RED BUTTON rela-

tionship, but

ONLY

when

Command 07 has been

programmed with a time

period. To control the

relay remotely, the opera-

tor needs to use the “6” on

the keypad to request the

contact closure for the time

period pre-programmed.

00-99 sec.

none

To force contact closure for 2 sec.

dial: 07-02-#, or for a contact clo-

sure of 60 sec. dial: 07-60-#

Figure 3