9 Troubleshooting

1. Check phone line

2. Is this a dial-up (1MB/POTS or ring down (hotline)) type service?

3. Loop Current: IA500 27mA to 50mA

4. Talk Battery: -24V DC to -48V DC

5. Ring Voltage: 90Vrms

Note: Only recommended for use on Bell POTS lines or dial tone provided by ToolVox

®

; locations with

private PBX head end phone systems should explore the rest of Code Blue’s speakerphone options.

Speakerphone programming manuals can be found at:

codeblue.com/Support/TechnicalSupport/downloads

If the IA500 doesn’t seem to be functioning properly, follow the steps below to test line loop current,

ring voltage and talk battery. These line levels are important to the proper function of the IA500.