Comtech EF Data CDM-750 User Manual

Page 173

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Ethernet-based Remote Product Management

MN-CDM750

6–29

• Rx Clock Source – Use the drop‐down list to select Tx Clock, Ext Clock, Rx Sat, or Int Clock. 

 

Comtech  EF  Data  strongly  recommends  that  you  select  Rx  Sat  unless  a  high 
stability  External  Clock  is  present  and  timing  of  the  network  requires  all 
devices to be locked to the External Clock.
 

 

• External Clock – Use the drop‐down list to set the expected clock rate for the External Clock 

source (via the CDM‐750 rear panel J8 | EXT REF connector) as 1 MHz, 2 MHz, 5 MHz, 10 
MHz
, 20 MHz, 34.368 MHz, 44.736 MHz, or 51.85 MHz. 
 

• Rx Buffer Size (ms) – Enter a buffer size, in 0.5 ms steps, ranging from 2 ms to 75 ms. 
 
Click [Configure PIIC] to save these settings. 

OC3 Configuration

• Interface Type – Use the drop‐down list to select None or OC3.  

 

• Tx Clock Source – Use the drop‐down list to select Tx Clock or Rx Sat. 

 

Comtech EF Data strongly recommends that you select Tx Clock unless a high 
stability  External  Clock  is  present  and  timing  of  the  network  requires  all 
devices to be locked to the External Clock.
 

 
• Rx Clock Source – Use the drop‐down list to select Tx Clock, Int Clk, or Rx Sat. 

 

Comtech  EF  Data  strongly  recommends  that  you  select  Rx  Sat  unless  a  high 
stability  External  Clock  is  present  and  timing  of  the  network  requires  all 
devices to be locked to the External Clock.
 

 

• Rx Buffer Size (ms) – Enter a buffer size, in 0.5 ms steps, ranging from 2 ms to 75 ms. 

Alarm Settings

• Tx Symbol Clock PLL – Use the drop‐down list to select Alarm, Fault, Mask, or Fault (Tx On). 

 

• Input Signal Loss – Use the drop‐down list to select Alarm, Fault, Mask, or Fault (Tx On). 
 
• Rx Buffer Clock PLL – Use the drop‐down list to select Alarm, Fault, or Mask. 
 
• Rx Buffer Overflow / Underflow – Use the drop‐down list to select Alarm, Fault, or Mask. 

 

• Ext Clock Activity (G.703 PIIC only) – (Indicates that the External Clock is selected by either 

the TxClock or RxClock but no clock is present on J8 | EXT REF.) Use the drop‐down list to 
select Alarm, Fault, Mask or Fault (Tx On). 
 

• Ext Clock In Range (G.703 PIIC only) –  (Indicates that the External Clock is selected by either 

the TxClock or RxClock, but the clock rate on J8 | EXT REF does not meet the expected rate 
by the CDM‐750.) Use the drop‐down list to select Alarm, Fault, Mask or Fault (Tx On). 