Comtech EF Data CDM-750 User Manual
Page 209

CDM-750 Advanced High-Speed Trunking Modem
Revision 2
Serial-based Remote Product Management
MN-CDM750
7–29
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
PIIC Rx Buffer
Size
RBS=
6 bytes
Command or Query.
Set or return Rx Buffer Size (in ms), in the form sxxx.x where:
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
xxx.x = Rx Buffer Size, in 0.5 ms steps, from 2.0 to 75.0 ms
Example: RBS=1032.5 (selects 32.5 ms for Slot 1)
RBS =
RBS?
RBS *
RBS #
RBS?s
RBS =
(see Description of
Arguments)
Re Center
Buffer
RCB=
None
Command only.
Force the software to recenter the receive buffer in the form x, where:
s = Interface Slot, where:
1 = Slot 1
2 = Slot 2
Example: RCB=2 (re-centers the buffer on the Slot 2 interface card)
RCBs=
RCB?
RCB#
RCB*
N/A
N/A