Table 11-40. utility parameters oids – Comtech EF Data CIM-300L User Manual
Page 281

CiM-300L IP Enabled Satellite Modem
Rev. 1
SNMP
CD/CIM300L.IOM
255
11.5.1.5 U
TILITY
P
ARAMETERS
Table 11-40. Utility Parameters OIDs
OID Description
cim300LOduPower
Can be set to:
0 Off
1 On
cim300LOduPower
Can be set to:
0 Off
1 On
cim300LOduThresholdLow
Range is 0 and 4000 in 100 mA steps.
cim300LOduThresholdHigh
Range is 0 and 4000 in 100 mA steps.
cim300LLnbPower
Can be set to:
0 Off
1 On
cim300LLnbVoltage
Can be set to:
13 13
Volts
18 18
Volts
24 24
Volts
cim300LLnbRefEnable
Can be set to:
0 Off
1 On
cim300LLnbThresholdLow
LNB Power Monitor Low Current Threshold. The value can
be between 0 and 500 in 1 mA steps.
cim300LLnbThresholdHigh
LNB Power Monitor High Current Threshold. The value can
be between 0 and 500 in 1 mA steps.
cim300LCarrierOnlyMode
Can be set to:
0 None
1 Dual
3 Offset
4 Center
cim300LIfLoopBack
Can be set to:
0 Off
1 On