Built-in diagnostic tests (efd_diag), Help screen, 13 built-in diagnostic tests (efd_diag) – Comtech EF Data SNM-1010L User Manual

Page 143: 1 help screen

Advertising
background image

SNM-1010L Data/Control Modem

Revision 0

User Port Operation

MN/SNM1010L.OM

4.3.13

Built-In Diagnostic Tests (EFD_DIAG)

Note: These tests shall be performed by qualified personnel only.

This command starts the DAC Diagnostic software:

EFD_DIAG'cr'

is 0 to select the SNM-1010L control channel.

Wait several seconds. The User Port will display:

•

Diagnostic Test, Press F1 for Help.

•

>

Enter an ANSI F1 function key character sequence to display the diagnostic main menu:

•

F1: Help Screen

•

F2: Transfer Control to Flash Loader

•

F3: Transfer Control to PDREM Ram

•

F4: Restore Area 1 Defaults

•

F5: Restore Area 2 Defaults

•

•

1: Run Ram test

•

2: Run NOVRAM cycle power test

•

3: Run Chip Select test

•

4: Run EFBUS1 to EFBUS2 loopback test

•

5: Run EFBUS2 to EFBUS1 loopback test

•

6: Run Service Terminal loopback test

•

7: Alarm Input Test


To leave the diagnostic tests and return to SNM-1010L operational code, enter an ANSI
F4 function key character sequence.

CAUTION

Selecting any menu selection other than “F4” may cause unpredictable
operation of the SNM-1010L.

4.3.13.1 Help

Screen

To display the menu selection for the Comtech EF Data diagnostics, select menu option
“F1” by entering an ANSI F1.






4–9

Advertising
This manual is related to the following products: