Local command responses, Pre-defined data circuit call (dc), Command format – Comtech EF Data SNM-1010L User Manual
Page 148: 2 local command responses, 2 pre-defined data circuit call (dc), 1 command format, Channel_no> dc <circuit_id>’cr

SNM-1010L Data/Control Modem
Revision 0
User Port Operation
MN/SNM1010L.OM
<tx_mod> and
<rx_mod>
Modulation.
Values:
Modulation
Type Code
BPSK
B
QPSK
Q
OQPSK
O
8PSK
8
<origin_clock> and
<dest_clock>
Clock Source.
Values:
Clock
Source Code
Terrestrial (TT)
T
Internal (ST)
I
Satellite (RT)
S
<grade_of_service> Optional
coding method indicator.
Values:
Coding
Method Code
Viterbi
V
(default)
Sequential
S
Turbo
T
4.3.16.1.2 Local Command Responses
<none>
Command received OK, will be sent to the NMS.
Error <code> : <description>
Code Description
9 Channel <Channel No.> Invalid
20 Not enough parameters.
4.3.16.2
Pre-defined Data Circuit Call (DC)
The user initiates a data call by specifying a pre-defined circuit. The circuit must be
pre-defined at the NMS.
4.3.16.2.1 Command
Format
<channel_no> DC <circuit_id>’cr’
<channel_no>
Prefix channel number. (Optional)
Valid range: 0 (or omitted)
DC
Pre-defined data circuit call.
<circuit_id> Pre-defined
circuit id at the NMS.
Valid range: 1 through 9999.
4–14