LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Updating Firmware

MN-LBC4000A

4–10

• Using  the  LBC‐4000  Web  Server  Interface  –  Using  the  ‘Next  Reboot  Image’  drop‐

down  menu  on  the    ‘Config  |  Utility’  page,  select  Latest,  1,  or  2,  and  then  click 
[Submit].  

 
 
 

By default, the unit will boot from the Slot storing the firmware version number that 
has the latest date (Next Reboot Image: Latest). ‘Next Reboot Image’ may also be 
set to force the unit to boot up using either firmware image loaded in Slot 1 or Slot 
2
. 
 

B. Reboot the LBC‐4000: 

 

• On the LBC‐4000 Web Server Interface ‘‘Config | Utility’ page, click [Reboot Now] in 

the  Perform  Soft  Reboot  section  of  the  page  to  reboot  the  LBC‐4000  using  the 
Current Active Firmware Image. Wait while the LBC‐4000 reboots. 
 

• Verify  the  new  firmware  version  has  booted  by  observing  the  firmware  version 

number  displayed  on  the  Converter  front  panel  (where  X.X.X  represents  the 
properly transferred firmware version number), for example: 

LBC-4000

Ver: X.X.X SN:XXXXXXXXX

 

5. To load the second image, repeat steps 2 through 4. 
 

The  LBC‐4000  is  now  operating  with  its  latest  firmware.  The  firmware 
update process is now complete. 