LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Ethernet-based Remote Product Management

MN-LBC4000A

6–23

6.4.5.3.5

Config | Serial

Use this page to configure LBC‐4000 operating parameters over the EIA‐485/232 serial interface. 
 
 
 
 
 
 
 
 
 
 
 

Figure 6-10. Config | Serial page

Serial

Use the drop‐down menu to select the operating serial mode as RS‐485 or RS‐232.  

Remote Address

Enter a valid remote control address from 0001 to 9999. 

Baud Rate

Use the drop‐down menu to select the operating baud rate as 100, 2400, 4800, 9600, 19200 or 
38400 baud. 

Data bits – Parity – Stop Bits

Use the drop‐down menu to select the asynchronous character format as 8‐N‐1 (8 data bits, no 
parity, 1 stop bit); 7‐O‐2 (7 data bits, odd parity, 2 stop bits); or 7‐E‐2 (7 data bits, even parity, 2 
stop bits). 
 
Click [Change Serial Configuration] to save these changes. 
 
To update the page with the latest available parameters, click [Refresh]. 
 
 
 

 