5 config | serial – Comtech EF Data LBC-4000 User Manual
Page 99

LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Ethernet-based Remote Product Management
MN-LBC4000A
6–23
6.4.5.3.5
Config | Serial
Use this page to configure LBC‐4000 operating parameters over the EIA‐485/232 serial interface.
Figure 6-10. Config | Serial page
Serial
Use the drop‐down menu to select the operating serial mode as RS‐485 or RS‐232.
Remote Address
Enter a valid remote control address from 0001 to 9999.
Baud Rate
Use the drop‐down menu to select the operating baud rate as 100, 2400, 4800, 9600, 19200 or
38400 baud.
Data bits – Parity – Stop Bits
Use the drop‐down menu to select the asynchronous character format as 8‐N‐1 (8 data bits, no
parity, 1 stop bit); 7‐O‐2 (7 data bits, odd parity, 2 stop bits); or 7‐E‐2 (7 data bits, even parity, 2
stop bits).
Click [Change Serial Configuration] to save these changes.
To update the page with the latest available parameters, click [Refresh].