Caution: Note that some actions, such as the Put command, may require

several minutes to be performed. Once an action is initiated, do not

attempt a subsequent action until the progress status (both the text

information and the progress bar(s)) indicates that the first action is

either completed, failed, or is terminated with the Cancel button.

Set Defaults / Clear

The upper button in the Progress area of the main window is a dual function

button. When no progess status information is displayed, the button label

appearance is Set Defaults. Clicking this button resets most VLoad parameters

to their initial default settings, as listed below.

•

Unit List

• Column order: IP Address, Type, Serial #, App Ver, Base Ver

• Column widths: 100, 90, 90, 72, 90 pixels

• Row order: ascending IP address

•

For each unit

• Transfer rate: 900 Kbps

• Port number: c001 hex (hard-coded)

• Attempts: 3 iterations

• Timeout: 3 seconds

• Reset type: hard

• Application

•

Next image to run: unchecked (current modem setting)

•

Next image to save: unchecked (current modem setting)

•

Next image to get: unchecked (current modem setting)

•

Flash timeout: 90 seconds (hard-coded)

• Base Modem

•

Next image to run: unchecked (current modem setting)

•

Next image to save: unchecked (current modem setting)

•

Flash timeout: 120 seconds (hard-coded)

• Configuration

•

Get from: active

•

Put to: active only

•

Flash timeout: 30 seconds (hard-coded)

• Unit Information

•

FAST code: none

•

Device type: none

•

Serial number: none

•

Name: none

•

Version: none

•

Network ID: none