DFI HR100-CRM User Manual

Page 24

Advertising
background image

24

2

Hardware Installation

JP2 is used to select the power of the PS/2 keyboard and PS/2 mouse ports. Se-
lecting +5V_standby will allow you to use the PS/2 keyboard or PS/2 mouse to
wake up the system.

PS/2 Power Select

JP2

2-3 On:

+5V_standby

1-2 On: +5V

(default)

Important:
The +5VSB power source of your power supply must support ≥720mA.

1

3

2

1

3

2