26

2

Hardware Installation

Panel Power Select

1-2 On: +12V

1

3

5

2
4

6

3-4 On: +5V

1

3

5

2
4

6

5-6 On: +3.3V

(default)

1

3

5

2
4

6

JP9

JP9 is used to select the power supplied to the LCD panel.

Important:
Before powering-on the system, make sure JP9’s setting matches the
LCD panel’s specifi cation. Selecting the incorrect voltage will seriously
damage the LCD panel.