GUIDE TO INSTALLATION



The following can be used as a checklist to verify all of the steps necessary for
complete installation of the Matrix-1000

 compact 2D reader.

1) Read all information in the section "Safety Precautions" at the beginning of this

manual.

2) Correctly mount the reader using the bracket provided (sub-pars. under 2.2).

3) Position the reader at the correct reading distance according to your model

(par. 2.5).

4) Make electrical connections to your Matrix-1000™ reader by either:

a)

Connecting the test cable to the Matrix-1000™ reader (par.2.4).

b)

Providing correct and complete system cabling according to the signals

necessary for the layout of your application.

Layout: Point-to-point or Multidrop, etc. (sub-pars: 2.6);

Cabling: Power, Main RS485, Auxiliary RS232, External Trigger Input

and Output (sub-pars. under 2.3).

5) Configure the Matrix-1000™ reader by installing and running VisiSet™ from the

CD-ROM provided onto the configuration PC (pars. 3.1, 3.2, 3.3). See the
Rapid Guide to Configuration in the VisiSet™ Help On Line. The main steps
are:

a)

Select the codes to be read

b)

Set-up the communication parameters

c)

Define data formatting parameters

d)

Fine tune your Matrix-1000™ reader using the VisiSet™ Calibration Tool

(par. 3.4.2).

Specific VisiSet™ parameter details are also available in the Help On Line.

6) Exit the configuration program and run your application.



The installation is now complete.