Calibration, Par. 3.4.2), 2 calibration – Datalogic Scanning MATRIX 1000 User Manual

Page 45

Advertising
background image

SOFTWARE CONFIGURATION

35

3

3.4.2 Calibration

VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning
the acquisition parameters and the time of the delayed triggers.

By selecting the Calibration Tool from the VisiSet™ Main Menu (F), the following
window appears together with the Parameter Setup window:

Figure 33 - Calibration OK


This tool provides a "real-time" image display while Matrix-1000™ is reading. It also
gives immediate results on the performance of the installed Matrix-1000™ reader.

The Parameter Setup window works in Interactive Mode in order to cause each
parameter setting to be immediately effective.

NOTE

If you want to save the temporary configuration to permanent
memory, you must first close the Calibration Tool window. Then,
you must disable the Interactive Mode and select the Permanent
Memory
option from the Send pars to reader item in the
Parameter menu.

Advertising