Min. | v, Max. i – Datalogic Scanning MATRIX 1000 User Manual

Page 30

Advertising
background image

Matrix-1000™

20

2

USER INTERFACE

MATRIX

V

CC

A

B

V

+

~

~

+

-

9

25

OUT

GND

GND

VS

Figure 18 - Input PNP Command Using Matrix-1000

Power

USER INTERFACE

VS

MATRIX

A

Vext

B

V

+

V

CC

~

~

+

-

GND

OUT

30 Vdc Max.

Figure 19 - Input NPN Command Using External Power

USER INTERFACE

VS

MATRIX

A

B

GND

V

+

V

CC

~

~

+

-

GND

9

OUT

25

Figure 20 - Input NPN Command Using Matrix-1000

Power


The electrical features of the input are:

INPUT |

V

AB

| Min.

| V

AB

| Max.

I

IN

Max

.

Open

0 V

2 V

0 mA

Closed

4.5 V

30 V

10 mA